Generator Test Set
|
|
30KW, 125/250VAC, 50-70 Hertz Load Bank
|
|
Reduce Wet Stacking in Diesel Powered Generators
Diesel-driven units are subject to particular malady known as "Wet Stacking" or "Slobbering" that stems from operation under no-load or light-load conditions. Such operations cause fuel deposits to collect on the combustion chamber, injector nozzles, piston rings, turbocharger and exhaust system. The result is diminished engine output capacity. Fully loading the generator for a time period will clear this condition.
|
|
Voltage Limits Identified
The proper voltage limits for both 120V and 240V generators are identified on the voltmeter face. |
|
Ammeter Controls
Dual ranges of 0-10 and 0-50 amps.
|
|
Direct Reading Frequency Meter
50-70 Hz (Electronic) frequency meter features a direct reading needle type indicator.
|
|
Self-Contained Cooling System
A self-contained fan allows the test set to operate on a continuous basis.
|
|
Built, Sold and Serviced in the
For over four decades Sotcher Measurement, Inc. has provided latest state-of-the-art electrical test equipment that is easy to use and maintain. Our customers rely on our products to verify the safety of the electrical devices they rent, use or manufacture. We feel this commitment very deeply. In response, we do our utmost to insure that the products we offer are of the highest quality and performance, consistent with good value.
|
|
We continue to design, manufacture and service all of our products in the United States. We are proud to be able to offer our customers fine American products that are easy to use at a practical price. |
|
Input Voltage:
|
120/240V, 50-70Hz, single phase |
|
Protection:
|
Circuit breaker protection provided on each section |
|
Load Capacity:
|
0-30,000 Watts |
|
Duty Cycle:
|
Continuous |
|
Power Factor:
|
Unity |
| Accuracies: |
|
|
• Frequency Meter:
|
+/-3% Center
|
| • Volt Meter: |
+/-3% FS.
|
| • Ammeter: |
+/-5% FS.
|
|
Input Plug:
|
3XCam-Lock Connectors, 400V, 125A |
|
Weight:
|
Approximately 50 pounds. |
|
Dimension:
|
12 inches high, 19 inches wide, 20 inches deep |
|
The following adapters allow you to mate the test set with receptacles commonly found on portable generators. Most of the adapters connect to the test set through the master adapter (40608). This saves you the cost of larger 50 amp connectors on every adapter. A good selection for most application would include the 40608, 40611,40612 and 40613.
|
|
|
40650: Adapter, Can Lock to Lugs, 125/250V, 125A
|
$230
|
|
40651: Adapter, 125/250V, mates with 40608
|
$250
|
|
40601: Adapter, 125/250V, 50A, with Clips
|
$186
|
|
40608: Adapter, Master, 125/250V, 30A, Locking
|
$120
|
|
40609: Adapter, 125/250V, 20A, Locking, mates with 40608
|
$78
|
|
40610: Adapter, 125V, 30A, Locking, mates with 40608
|
$74
|
|
40611: Adapter, 125V, 20A, Locking, mates with 40608
|
$68
|
|
40612: Adapter, 125V, 15A, Non-Locking, mates with 40608
|
$63
|
|
40613: Adapter, 240V, 20A, Locking, mates with 40608
|
$68
|
|
40614: Adapter, 125/250V, 50A, Locking
|
$168
|
|
40616: Adapter, 125/250V, 50A, with Lugs
|
$202
|
|
40617: Adapter, 250V, 20A, Locking
|
$68
|
|
40619: Adapter, 125/250V, 50A, 3 Phase, Locking (two test sets)
|
$294
|
|
• Model 650 30KW Generator Test Set
|
|
• User's Manual
|
|